OC‑1000 portable exhaust gas analyzer with built‑in adjustable pump, supports customizable SO2, NO2, CO toxic gas sensors, max 5 gas channels. Ex ia IIC T4 Ga explosion‑proof, IP65, 100000‑group data storage for industrial exhaust spot‑testing and environmental field inspection. Request quotation.

✅ Request A Quote
Share your exhaust‑gas testing requirements, we reply you within 24 working hours.
OC‑1000 portable exhaust gas analyzer is a hand‑held pump‑suction multi‑gas measuring instrument for on‑site exhaust‑gas and industrial emission spot‑check. Adopting ultra‑low‑power 32‑bit micro‑processor and high‑precision 24‑bit ADC acquisition chip, it achieves reliable field‑measurement performance. The instrument supports up to 6 sensor slots; temperature‑humidity sensor is default built‑in.
For gas‑only measurement: it can load maximum 5 gas sensors. If particle‑dust sensor is added, it can configure up to 3 gas sensors. Sensor combination can be fully customized, typical configuration includes SO₂, NO₂, CO for exhaust‑gas inspection.
Equipped with adjustable‑strength built‑in suction pump, it works well under micro‑negative‑pressure environment, matched with external sampling probe for remote exhaust‑gas extraction. It stores up to 100 000 groups test data, which can be exported to PC by supporting software. Optional mini‑printer supports on‑site printed records.
With Ex ia IIC T4 Ga intrinsic‑safety explosion‑proof grade and IP65 housing, OC‑1000 fits complex industrial field conditions for environmental enforcement sampling, factory exhaust screening and workshop hazard‑gas patrol.
‑ Industrial Exhaust & Flue‑gas Spot‑sampling: Factory exhaust, boiler emission field screening test.
‑ Environmental Enforcement & Third‑party Labs: Outdoor waste‑gas investigation, EIA baseline field survey.
‑ Petrochemical & Chemical Plants: Workshop toxic‑gas patrol inspection.
‑ Metallurgy & Power Industry: Plant‑site harmful‑gas spot‑detection.
‑ Biopharmaceutical & Agricultural Sites: Production‑area atmosphere hazard assessment.
‑ Confined‑space Pre‑entry Safety Test: Pre‑detection before personnel entering tanks and closed pipelines.

‑ Flexible multi‑sensor configuration: Max 6 sensor positions (default temp‑humidity sensor); up to 5 gas‑only channels, or max 3 gas sensors when particle sensor is installed; gas combinations fully customizable.
‑ Adjustable built‑in pump‑suction: Multi‑level suction‑strength setting, supports micro‑negative‑pressure working, cooperate with sampling probe for remote exhaust‑gas collection.
‑ 3.5‑inch IPS industrial color screen: Clear display of date, time, temperature‑humidity, gas concentration, unit, pump / alarm / battery status. Chinese / English menu switchable.
‑ Multiple engineering‑units available: ppm, %vol, %LEL, mg/m³ for different reporting standards.
‑ Dual‑stage audible‑visual‑vibration alarm: Adjustable alarm threshold; trigger alert once concentration exceeds preset value.
‑ Auto‑diagnosis & one‑key factory reset: Power‑on self‑test, one‑click restore factory‑default parameters. Temperature & pressure compensation to reduce environment‑caused deviation.
‑ Large‑capacity data log: Store up to 100 000 groups records; data export to PC via software; optional mini‑printer for on‑site printout.
‑ Complete circuit‑protection design: Over‑load, over‑charge, anti‑static, anti‑magnetic‑interference protection.
‑ Field‑ready safety grade: Ex ia IIC T4 Ga intrinsic‑safety explosion‑proof, IP65 ABS+PC housing, lightweight handheld design for mobile field missions.
| Item | OC‑1000 Exhaust‑gas Version Specification |
|---|---|
| Measured Gases | SO₂, NO₂, CO (customizable gas composition) |
| Sensor Principle | Electrochemical sensor |
| Sampling Mode | Pump‑suction sampling, adjustable suction strength |
| Measuring Range | SO₂:0‑1000 ppm;NO₂:0‑1000 ppm;CO:0‑5000 ppm;ranges can be customized |
| Resolution | 1 ppm |
| Response Time(T90) | ≤ 20 s |
| Recovery Time | ≤ 20 s |
| Repeatability | ≤ ±1 % |
| Linearity | ≤ ±1 % |
| Zero Drift | ≤ ±1 % F.S / year |
| Concentration Unit | ppm, %vol, %LEL, mg/m³ |
| Display | Show date, time, temp‑humidity, gas concentration, unit, pump / alarm / battery status |
| Operation Language | Chinese / English |
| Alarm Mode | Audible, visual, vibration dual‑stage alarm |
| Data Storage | Max 100 000 groups of measuring data; data export to PC by supporting software |
| Printer | Optional mini‑printer |
| Working Temperature | −40 ℃ ~ 60 ℃ |
| Working Humidity | 0‑95 %RH (non‑condensing) |
| Working Pressure | −30 kPa ~ 100 kPa |
| Explosion‑proof Grade | Ex ia IIC T4 Ga |
| Protection Grade | IP65 |
| Shell Material | ABS + PC |
| Dimension | 220 × 88 × 55 mm |
| Weight | 0.5 kg |
| Standard Accessories | Particle filter, carrying case, instruction manual, USB charger, data cable, calibration cap |
Remark: Gas types and measuring‑ranges can be fully customized according to your exhaust‑gas‑testing project, please confirm with sales team.
Each OC‑1000 analyzer completes strict factory inspection before shipment:
Incoming inspection for sensors, PCB and housing parts
Assembly and circuit continuity check
Full‑function power‑on test
Multi‑point gas calibration for each installed sensor
Aging stability test
Final outgoing FQC inspection before packing
Calibration‑test records are available upon commercial request. CE & RoHS compliant.

Company profile
We Henan Oceanus is located in Henan, a land with a long history and profound cultural heritage, has been dedicated to the research, development, production, and sales of Gas detection system and Environment equipments since its establishment. With exquisite technology and outstanding quality, we have won widespread recognition in the global marketing.

Manufacturing & Quality Control
Every Detail Matters. Every Product Deserves Care.
At Oceanus, quality is considered throughout the manufacturing process. From component inspection and product assembly to performance verification and final inspection, we focus on every detail to ensure our products meet the applicable quality requirements before delivery.
Product Inspection
Each product undergoes visual and functional checks to verify component assembly, wiring connections, display operation and basic functionality before delivery.

Product Aging Test
Aging tests are conducted on applicable products to evaluate operational stability and identify potential issues during continuous operation.

Calibration & Performance Verification
Measuring performance is verified using appropriate reference equipment and standard gases, where applicable, to help ensure reliable measurement results.

Final Inspection Before Delivery
Before shipment, products are checked for appearance, accessories, packaging and order-specific requirements to ensure delivery readiness.

Every unit is assembled on our own production line, then put through our in-house quality control before it ships. Each instrument undergoes a full inspection, a burn-in aging test and precision calibration, and is finally standardized against reference gases to verify accuracy at the point of delivery. Nothing leaves our factory untested. We also welcome OEM and ODM projects, and every product is backed by our warranty support. Controlling the process from assembly to final calibration is how we keep quality consistent and respond quickly to custom requirements.

Please inform us target‑gas species, measuring‑range, whether you need particle‑dust function, accessories requirement and project quantity. We will recommend suitable sensor‑configuration for your exhaust‑gas spot‑testing work.
How To Cooperate With Us?
We look forward to collaborating with more overseas gas detector and air quality monitor distributors and partners to advance the development and application of gas detection and air quality monitoring technologies .
Our Address
No. 923, Floor 9, Unit 2, NO.78, Shangding Road, Zhengzhou, China.
Phone Number
+86 15981942832
Contact:Oceanus Team
Mobile/WhatsApp:+86 15981942832
Mobile/WhatsApp:+86 13673683950
E-mail:info@china-oceanus.com
Add:No.923, Floor 9, Unit 2, NO.78, Shangding Road, Zhengzhou, China