OC‑2000 portable multi‑gas detector supports 1‑12 configurable gas sensors, pump‑suction sampling, Ex ia II C T6 explosion‑proof, 100000 groups data logging. Widely deployed for overseas petrochemical spot checking, waste‑gas field sampling and confined‑space safety testing. Request project quotation.

OC‑2000 portable multi‑gas analyzer is field‑proven industrial gas‑testing instrument for on‑site spot‑sampling projects. Built‑in 32‑bit MCU and high‑precision 24‑bit ADC chip, this unit supports flexible configuration from 1 up to 12 different gas sensors, matching diverse field‑measurement tasks.
Equipped with high‑flow built‑in suction pump, it can realize remote sampling up to 5 meters and works reliably under micro‑negative‑pressure environment. Two working modes are available: real‑time instantaneous reading and timed‑average‑value measurement, storing up to 100 000 groups of detection records.
Rich optional accessories include mini on‑board printer, high‑temperature sampling probe, temp‑humidity sensor, long‑distance wireless transmitter and GPRS remote transmission module. With Ex ia II C T6 intrinsic‑safety explosion‑proof grade and IP65 enclosure, the instrument has been adopted in multiple overseas environmental‑inspection, petrochemical and metallurgy projects for complex harsh‑site operations.
‑ Petrochemical & Refinery Sites: Pipeline & tank‑area gas‑leak spot inspection, process‑gas field sampling.
‑ Environmental Testing & Third‑party Institutes: Waste‑gas spot survey, emission‑screening test, field environmental baseline assessment.
‑ Confined‑space Pre‑entry Safety Testing: Pre‑detection for tanks, reaction vessels and closed pipelines before personnel access.
‑ Metallurgy & Chemical Plants: Routine safety‑patrol and toxic‑hazard‑gas inspection.
‑ Biopharmaceutical & Agricultural Sites: Workshop & farm‑site atmospheric‑condition field investigation.
‑ High‑temperature flue‑gas spot‑sampling: Match optional high‑temperature sampling probe for furnace‑exhaust testing.

‑ Multi‑sensor expandable: Freely configure 1‑12 gas sensors; support catalytic combustion, electrochemical, infrared‑NDIR and PID sensor technologies for various target gases.
‑ Built‑in powerful pump‑suction system: Max sampling distance up to 5 m, stable operation under micro‑negative‑pressure; optimized gas‑chamber design protects sensors from pressure impact.
‑ 3.5‑inch industrial‑grade color display: Readings can be shown in ppm, %vol, mg/m³ units; automatic self‑diagnosis for sensors, chips and hardware after power‑on.
‑ Massive local‑data storage: Max 100 000 groups of measurement records; optional mini‑printer supports manual / auto‑interval print output for on‑site filing.
‑ Dual‑measurement modes: Real‑time reading and timed‑average‑value measurement to satisfy different field‑test purposes.
‑ Multi‑point automatic sensor calibration: Up to 6‑point calibration supported, full‑span temperature compensation; one‑key restore factory‑default parameters.
‑ Complete circuit‑level protection: Over‑charge, over‑voltage, short‑circuit, anti‑static and anti‑magnetic‑interference protection.
‑ Intrinsic‑safety explosion‑proof Ex ia II C T6, IP65 housing for complex outdoor‑field environments.
‑ Rich optional hardware modules: High‑temperature sampling probe, temp‑humidity sensor, wireless / GPRS remote‑transmission unit.
| Item | OC‑2000 Specification |
|---|---|
| Detectable Gas Types | Combustible gas, O₂, toxic gases, CO₂, TVOC etc. (1‑12 sensors configurable) |
| Sensor Options | Catalytic combustion, Electrochemical, Infrared‑NDIR, PID |
| T90 Response Time | ≤20 s |
| Repeatability | ≤ ±1 % FS |
| Linearity | ≤ ±1 % FS |
| Zero Drift | ≤ ±1 % FS / year |
| Sampling Mode | Built‑in pump‑suction, flow rate 2 L/min; max sampling distance 5 m; adapt micro‑negative‑pressure |
| Working Mode | Real‑time measurement / Timed‑average‑value measurement |
| Data Storage | Max.100 000 groups records; real‑time & timed‑storage |
| Optional mini‑printer; adjustable print interval, auto‑print / manual‑print | |
| Self‑check Function | Battery, screen, sensor & hardware automatic diagnosis |
| Alarm Mode | Audible‑visual dual‑alarm |
| Explosion‑proof Grade | Ex ia II C T6 |
| Protection Grade | IP65 |
| Working Temperature | ‑30 ℃ ~ +60 ℃ |
| Working Humidity | ≤95 %RH (non‑condensing) |
| Working Pressure | ‑30 kPa ~ 100 kPa |
| Power Supply | 6000 mAh rechargeable lithium‑ion battery |
| Dimension(L×W×H) | 230 × 120 × 220 mm |
| Weight | 2.5 kg |
| Optional Accessories | High‑temperature sampling probe, temp‑humidity module, wireless transmitter(1000‑3000 m), GPRS remote‑transmission |
Measuring range, power supply and optional modules can be configured to match local regulation and project requirements. Please contact our team for confirmation.

Every Detail Matters. Every Product Deserves Care.
At Oceanus, quality is considered throughout the manufacturing process. From component inspection and product assembly to performance verification and final inspection, we focus on every detail to ensure our products meet the applicable quality requirements before delivery.

Product Inspection → Product Aging Test → Calibration & Performance Verification → Final Inspection Before Delivery
Before shipment, products are checked for appearance, accessories, packaging and order-specific requirements to ensure delivery readiness.
Please tell us target‑gas species, measuring‑range, required optional accessories and your field‑working‑conditions. Our team will recommend suitable sensor‑configuration for your spot‑testing scenarios.
How To Cooperate With Us?
We look forward to collaborating with more overseas gas detector and air quality monitor distributors and partners to advance the development and application of gas detection and air quality monitoring technologies .
Our Address
No. 923, Floor 9, Unit 2, NO.78, Shangding Road, Zhengzhou, China.
Phone Number
+86 15981942832
Contact:Oceanus Team
Mobile/WhatsApp:+86 15981942832
Mobile/WhatsApp:+86 13673683950
E-mail:info@china-oceanus.com