Search

Fixed gas detector

OC‑F08 Fixed 4‑in‑1 Gas Detector

OC‑F08 fixed 4‑in‑1 gas detector for continuous site monitoring: Combustible gas, H2S, CO, O2. Ex d IIC T6 flame‑proof, IP66, 4‑20mA / RS485 / relay output, compatible with PLC & DCS for petrochemical, mining, wastewater‑treatment plant safety monitoring. Request quotation.

OC‑F08 Fixed 4‑in‑1 Gas Detector

Wall‑Mount Explosion‑Proof 4‑Gas Transmitter For Continuous Industrial Site Gas Safety Monitoring

64x64

Overview

OC‑F08 series Fixed gas detector adopts imported high‑precision sensors and ultra‑low‑power 32‑bit microprocessor hardware platform, delivering stable, repeatable and fast‑response gas measurement for hazardous industrial locations.

This 4‑in‑1 version simultaneously monitors Combustible gas, H₂S, CO and O₂ via diffusion sampling. Multiple signal outputs including 4‑20 mA analog, RS485 digital and optional relay signal enable seamless integration with PLC, DCS, local alarm controller and industrial computer, supporting remote real‑time monitoring, alarm triggering and historical data logging.

With Ex d IIC T6 flame‑proof certification and IP66 cast‑aluminum housing, the unit is designed for long‑term 24/7 continuous operation under harsh plant‑site environments. Infrared remote‑control operation allows parameter setup without opening the enclosure in explosive‑risk zones. Modular sensor architecture simplifies on‑site maintenance and replacement work.


Main Applications

‑ Petrochemical & Refineries: Plant area continuous monitoring for combustible and toxic gas leakage. 

‑ Mining & Coking Plant: Underground‑entrance and workshop‑boundary gas safety supervision. 

‑ Metallurgy & Power Station: Workshop toxic‑gas hazard early‑warning. 

‑ Sewage‑Treatment Facilities: H₂S and oxygen monitoring at digestion tanks and pumping stations. 

‑ Pharmaceutical & Chemical Manufacturing: Production‑area flammable‑toxic gas real‑time surveillance. 

‑ Marine & On‑board Installation: Hazard‑zone gas monitoring for ship cabin areas. 

‑ Municipal & Environmental Projects: Gas‑risk monitoring for chemical‑storage zones.

fixed gas detector2.jpg

Core Advantages & Key Features

‑ 4‑in‑1 multi‑gas measurement: Combustible gas, H₂S, CO, O₂, diffusion‑type sampling. 

‑ Multiple industry‑standard signal outputs: 4‑20 mA analog, RS485 Modbus digital, 200‑1000 Hz frequency signal, optional relay alarm output. Easy integration with PLC, DCS and third‑party control systems. 

‑ Modular intelligent sensor design: Independent air‑chamber structure; sensors support auto‑parameter identification. No full‑unit re‑calibration required after sensor replacement for easier site maintenance. 

‑ Non‑intrusive infrared remote‑controller operation: Complete configuration without opening the housing inside hazardous classified areas. 

‑ High‑reliability hardware: 16‑bit ADC chip and four‑layer PCB design for strong anti‑electromagnetic‑interference performance. 

‑ Local LCD display: Real‑time readout for gas concentration, gas type, engineering unit and instrument working status. Concentration units: ppm, %LEL, %vol, mg/m³ selectable. 

‑ Flame‑proof & robust enclosure: Ex d IIC T6 explosion‑proof grade, IP66 cast‑aluminum housing, suitable for demanding outdoor and indoor industrial zones. 

‑ Wide working condition adaptability: Operates at ‑30 ℃ ~ 60 ℃; optional filter module for high‑humidity sites.


Company Profile

We Henan Oceanus is located in Henan, a land with a long history and profound cultural heritage, has been dedicated to the research, development, production, and sales of Gas detection system and Environment equipment since its establishment. With exquisite technology and outstanding quality, we have won widespread recognition in the global marketing.

1

Manufacturing & Quality Control

Every Detail Matters. Every Product Deserves Care.

At Oceanus, quality is considered throughout the manufacturing process. From component inspection and product assembly to performance verification and final inspection, we focus on every detail to ensure our products meet the applicable quality requirements before delivery.

  • Power‑on test

Each product undergoes visual and functional checks to verify component assembly, wiring connections, display operation and basic functionality before delivery.

d74fae67ea643cea444190c537a7a469_720.jpg


  • Product Aging Test

Aging tests are conducted on applicable products to evaluate operational stability and identify potential issues during continuous operation.

5a81fef44ec129de78df74213763c098_720.jpg

  • Calibration & Performance Verification

Measuring performance is verified using appropriate reference equipment and standard gases, where applicable, to help ensure reliable measurement results.

image.png


  • Final Inspection Before Delivery

Before shipment, products are checked for appearance, accessories, packaging and order-specific requirements to ensure delivery readiness.

1793949240107651.jpg

Technical Specifications

ItemOC‑F08 4‑in‑1 Version Specification
Measured GasesCombustible gas, H₂S, CO, O₂
Measuring RangeCombustible gas:0‑100%LEL;H₂S:0‑100 ppm;CO:0‑1000 ppm;O₂:0‑30 %VOL
ResolutionCombustible gas:0.1%LEL;H₂S:0.1 ppm;CO:1 ppm;O₂:0.01 %VOL
Sensor TechnologyCombustible gas:Catalytic combustion; H₂S/CO/O₂:Electrochemical
Sampling ModeDiffusion sampling
Accuracy≤ ±3 %FS
Repeatability≤ ±1 %FS
Zero Drift≤ ±1 %FS / year
Sensor Service Life2‑3 years
T90 Response Time≤ 20 s
Working EnvironmentTemp:‑30 ℃ ~ 60 ℃(custom available); Humidity ≤95 %RH(non‑condensing); Pressure:86‑106 kPa
Working Voltage24 V DC (16‑30 VDC)
Signal Output4‑20 mA, RS485, RJ45; optional relay & 200‑1000 Hz frequency output
Housing MaterialCast aluminum
Explosion‑proof GradeEx d IIC T6
Protection GradeIP66
Max Transmission Distance≤2000 m (repeater needed for longer distance)
Dimension265 × 232 × 80 mm(L×W×H)
WeightApprox.2.4 kg
Compliance StandardsGB15322.1‑2003, GB3836.1‑2010, GB3836.2‑2010, GB3836.4‑2010
Warranty12‑month warranty for main unit

Remark: Custom gas combinations, measuring‑ranges and signal‑interface requirements are acceptable, please contact sales for project‑specific confirmation.


证书合集.png

Get Your Project‑Tailored Proposal

Please inform us target‑gas configuration, installation environment, required signal‑output type and quantity. Our engineering team will give configuration suggestions and quotation for your industrial monitoring project.


How To Cooperate With Us?

We look forward to collaborating with more overseas gas detector and air quality monitor distributors and partners  to advance the development and application of gas detection and air quality monitoring technologies .

Our Address

No. 923, Floor 9, Unit 2, NO.78, Shangding Road, Zhengzhou, China.

Phone Number

+86 15981942832

E-Mail

info@china-oceanus.com


INQUIRY

CATEGORIES

CONTACT US

Contact:Oceanus Team

Mobile/WhatsApp:+86 15981942832

Mobile/WhatsApp:+86 13673683950

E-mail:info@china-oceanus.com

Add:No.923, Floor 9, Unit 2, NO.78, Shangding Road, Zhengzhou, China