Search

Fixed gas detector

OC‑F08 Fixed N2 Detection Device

OC‑F08 Fixed N2 Detection Device is industrial‑grade fixed nitrogen gas monitor, equipped with imported sensor and 32‑bit ultra‑low‑power microprocessor. It measures nitrogen concentration or monitors oxygen deficiency caused by N₂ displacement. It supports 4‑20mA, RS485 and relay output, connects to PLC/DCS system, realizes real‑time monitoring, remote alarm and data logging for inert gas protection in industrial sitesAlibaba

Description:

OC-F08 fixed gas detection device can be connected with the control system, with remote monitoring alarm, analysis function and data recording function. Imported sensors are adopted, with high precision, good repeatability, stable signal and fast response. Gas can be customized.


Common applications is gas safety inspection and alarm for industrial scene, such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection, etc., where need to inspect the gas concentration.


Features:
4-20mA standard analog signal and RS485 digital signal output, 200~1000HZ signal output, relay output, data restore, data logger (optional);

LED screen displaying the gas concentration, gas type, unit, instrument status etc.

Independent air chamber, the sensor is not required to replace the sensor calibration, automatic identification of key parameters of the sensor

Protection function to prevent high gas concentration attack.

Display the gas concentration in %vol.

Infrared remote controller operation;

With the 16bit ADC acquisition chip, designed with four-layer circuit board, so with high anti-interference ability.

With the Ex-proof certificate, the Ex-proof grade is Exd II CT6.


Examples of technical parameters:

Applicable Gas

Nitrogen (N2)

Detecting Range

0-100%Vol、0-99.99%VOL、0-99.9%VOL or customized

Resolution

0.1%VOL、0.01%VOL

Sampling

Diffusion or pump-suction, circulation selectable

Accuracy

≤±3%F.S

Repeatability

≤±1%

Zero drift

≤±1%(F.S/year)

Sensor Type

Electrochemical sensor

Sensor Life

2~3 years

Response Time (T90)

≤20s

Alarming mode

Audible-visual alarm(Optional)

Operating Environment

Temperature: -30℃~60℃ (Customized for special demands)

Humidity: ≤95%RH (non-condensing); if >90%RH, can add the filter

Pressure: 86kPa~106kPa

Working Voltage

24V DC(16~30VDC)

Output Signals

(Standard)Three-wire system 4~20mA standard signals output, available for PLC, DCS, etc;

(Optional) Four-wire system RS485 digital signal output;

(Optional) Frequency signal 200~1000Hz output;

Two-level relay output:220VAC 0.5A, 5VDC 0.5A

Installation Means

Wall mounted, Pipe type(Thread:M40*1.5 )

Material of Body

Cast aluminum

Explosion-proof Index

Ex d IIC T6

Protection Grade

IP66

Electrical Interface

3/4″NPT(Female Screw)、1/2″NPT(Female Screw)

Transmit Distance

≤2000m

Dimension

210 mm×140 mm×92 mm(L×W×H)

Weight

About 1.5Kg

Warranty

12 months

Standards

GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010

Company Profile

We Henan Oceanus is located in Henan, a land with a long history and profound cultural heritage, has been dedicated to the research, development, production, and sales of Gas detection system and Environment equipment since its establishment. With exquisite technology and outstanding quality, we have won widespread recognition in the global marketing.

1

01

Business areas

As a leader in the field of Gas detector and Air quality monitor system, we Henan Oceanus will be continued to expand its business scope and provide customers around the world with customizable Air quality monitor system of various types and specifications.

02

Values and ideas

Our company upholds the core values of integrity and quality service, focusing more on friendship with our customers. We always adhere to integrity management, customer-centered, and provide a full range of pre-sales, sales, and after-sales services to ensure that customers can be worry-free when using our products.

03

Global Service Network

We have a comprehensive global service network, offering timely, professional pre-sales consultation, after-sales service, and technical support for overseas users. Regardless of where users are located, they can enjoy our attentive and thoughtful service.

04

Custom Service

With excellent products and services, Henan Oceanus Gas detector and Air quality monitor system have been exported to more than 100 countries around the world and have won widespread praise.

64x64


Our After-sales service:

1. OEM service for LOGO, model, Technical Parameters, Operation manual, etc.

2. Free calibration service and provide calibration methods.

3. One year warranty and lifetime warranty


How To Cooperate With Us?

We look forward to collaborating with more overseas gas detector and air quality monitor distributors and partners  to advance the development and application of gas detection and air quality monitoring technologies .

Our Address

No. 923, Floor 9, Unit 2, NO.78, Shangding Road, Zhengzhou, China.

Phone Number

+86 15981942832

E-Mail

info@china-oceanus.com

INQUIRY

CATEGORIES

CONTACT US

Contact:Oceanus Team

Mobile/WhatsApp:+86 15981942832

Mobile/WhatsApp:+86 13673683950

E-mail:info@china-oceanus.com

Add:No.923, Floor 9, Unit 2, NO.78, Shangding Road, Zhengzhou, China