Search

Air quality monitor station

AQM‑09 Outdoor Multi‑Parameter Air Quality Monitoring Station | For Construction, Mining & Urban Fenceline Projects

AQM‑09 modular outdoor air quality station monitors PM1/PM2.5/TSP, toxic gases, noise and full meteorological data. Proven field‑tested in Kazakhstan, Myanmar, UAE quarry projects. Request quotation for your environmental monitoring project.

AQM‑09 Outdoor Multi‑Parameter Air Quality Monitoring Station

Field‑proven ambient monitoring solution for construction sites, quarries, industrial plants and urban environmental grid deployment

1794551762527860.pngOverview

The AQM‑09 outdoor air quality monitoring station is a modular, all‑in‑one environmental monitoring terminal developed for complex field conditions. Integrating particulate detection, multi‑gas sensing, noise measurement and full set meteorological sensors, it adopts industrial imported sensor technology plus built‑in automatic heating‑dehumidification compensation module to minimize data drift caused by high‑humidity outdoor environment.

Designed for large‑scale grid layout, AQM‑09 supports flexible sensor configuration according to project requirements. It delivers stable 24/7 real‑time data via 4G/GPRS dual‑channel transmission, with breakpoint resume to avoid data loss under unstable network. It supports external LED public display screen, alarm lamp and linkage with on‑site dust‑suppression sprinkler systems. Multiple installation options including pole‑mount and tripod‑mount meet different site deployment needs.

Core Application Scenarios

AQM‑09 has been widely deployed in multiple overseas real‑world projects:

  • Construction & Railway‑upgrade Projects: Real‑time PM & noise monitoring for job‑site compliance; linkage with sprinkler dust reduction facilities.

  • Quarry & Mining Sites: Monitor fugitive dust and surrounding air quality for stockpile & crushing zones.

  • Cement & Manufacturing Plants: Plant fenceline emission supervision and over‑limit alarm notification.

  • Smart City Public Zones: Streets, airports, communities, schools, tourist parks for urban grid environmental monitoring.

  • Road & Transportation Corridors: Traffic‑related dust, noise and meteorological condition tracking.

Real‑world Project References

客户返图 (16).jpg

Project: Tropical Coastal Ambient Air Quality Monitoring ProjectThis on-site photo shows AQM‑09 air quality monitoring station deployed at a tropical coastal ecological monitoring site. The site is surrounded by dense forest, adjacent to the sea, with high humidity, strong sea salt fog and complex meteorological conditions. The AQM‑09 system is set up on portable tripods for temporary field air quality survey. It continuously monitors particulate matter, gaseous pollutants, noise and meteorological parameters. The built-in humidity compensation and anti-corrosion design ensures stable data output under humid coastal marine climate. The portable tripod mounting method supports flexible layout for environmental baseline investigation, ecological assessment and regular air quality sampling. Multiple monitoring devices are arranged synchronously to compare and verify the data accuracy of the whole monitoring network.


Manufacturer Quality & Reliability

Every Detail Matters. Every Product Deserves Care.

At Oceanus, quality is considered throughout the manufacturing process. From component inspection and product assembly to performance verification and final inspection, we focus on every detail to ensure our products meet the applicable quality requirements before delivery.

  • Waterproof Testing

As air quality monitors are mainly used for outdoor monitoring, they need to withstand different weather conditions. Therefore, we conduct waterproof testing to evaluate their water resistance and ensure reliable outdoor operation.

  • Environmental Reliability Test

Environmental reliability testing evaluates product performance under high and low temperatures, varying humidity levels, and other environmental conditions to ensure stability and adaptability.

  • Mechanical Durability Testing

Mechanical durability checks help evaluate enclosure integrity, structural stability and resistance to applicable mechanical stresses.

  • Final Inspection Before Delivery

Before shipment, products are checked for appearance, accessories, packaging and order-specific requirements to ensure delivery readiness.

Key Features

  • Flexible modular architecture: Add / remove monitoring parameters to match project requirements.

  • Particle measurement: Simultaneous PM1, PM2.5, PM10, TSP measurement, no frequent sampling‑cutter replacement required.

  • Multi‑detection principle: Light‑scattering, electrochemical, PID and infrared sensor options for different gas targets.

  • Auto heating & dehumidification: Effectively reduce humidity‑induced measurement deviation for outdoor sites.

  • Dual‑channel communication + breakpoint resume: ≥95% effective data transmission rate under unstable field network.

  • 4G/GPRS wireless upload: Real‑time data synchronize to cloud monitoring platform.

  • External peripheral support: Compatible with outdoor LED display, alarm strobe light, sprinkler linkage control.

  • Flexible installation: Pole, tripod mounting solutions for temporary and permanent deployment.


General System Specifications

ItemAQM‑09 Specification
Cabinet MaterialQ235 spray‑coated; stainless steel optional
ScaffoldQ235 galvanized, standard height 4.5 m
Protection GradeIP55
Power SupplyAC220V / 50Hz; solar‑power kit optional for off‑grid sites
Communication4G / GPRS, RS485, network port
Working Temperature‑20 ℃ ~ +50 ℃
Working Humidity5 %RH ~ 95 %RH
Sampling ModeBuilt‑in pump‑suction sampling system
Data Transmission Rate≥95 %
Remote ControlSupport remote parameter configuration


Particulate Module

ItemSpecification
Measuring PrincipleLaser light scattering
Measured ObjectsPM1, PM2.5, PM10, TSP
Measuring Range0‑1000 μg/m³ (range extendable)
Resolution1 μg/m³
Response Time≤60 s
Accuracy≤100 μg/m³: ±10 μg/m³;>100 μg/m³: ±10 % reading
Sampling Flow1.3 L/min ±0.15


Gaseous Pollutants (optional selection)

GasRangeResolutionResponse Time
SO₂0‑2000 ppb1 ppb<45 s
NO₂0‑2000 ppb1 ppb<45 s
O₃0‑2000 ppb1 ppb<45 s
CO0‑200 ppm0.1 ppm<45 s
CO₂0‑5000 ppm1 ppm<45 s
TVOC0‑50 ppm0.1 ppm<45 s
H₂S0‑100 ppm0.1 ppm<45 s
NH₃0‑100 ppm0.1 ppm<45 s


Meteorological & Noise Parameters

ParameterSpecification
Temperature‑40 ~ +85 ℃, ±1 ℃ precision
Humidity0‑95 %RH, ±5 %RH precision
Wind Direction0‑360°, ±3° precision
Wind Speed0‑30 m/s
Barometric Pressure600‑1110 hPa
Rainfall, Solar Irradiance, IlluminationOptional module
Noise30‑130 dB(A), A/C/Z frequency weighting

Remark: Custom measuring ranges and sensor combinations are supported. Please contact sales for special‑requirement confirmation.


Get Your Project‑Tailored Proposal

Tell us your site environment, required sensor list, power supply condition and deployment scale. Our team will recommend suitable configuration and offer quotation.

How To Cooperate With Us?

We look forward to collaborating with more overseas gas detector and air quality monitor distributors and partners  to advance the development and application of gas detection and air quality monitoring technologies .

Our Address

No. 923, Floor 9, Unit 2, NO.78, Shangding Road, Zhengzhou, China.

Phone Number

+86 15981942832

E-Mail

info@china-oceanus.com

INQUIRY

CATEGORIES

CONTACT US

Contact:Oceanus Team

Mobile/WhatsApp:+86 15981942832

Mobile/WhatsApp:+86 13673683950

E-mail:info@china-oceanus.com

Add:No.923, Floor 9, Unit 2, NO.78, Shangding Road, Zhengzhou, China